LIFE SAFETY & EMERGENCY EVACUATION MOBILITY

Certified Fire Evacuation & Fireman Elevators

Purpose-engineered for emergency civilian evacuation and dedicated first-responder fire operations in high-rise buildings. Fully compliant with the National Building Code (NBC 2016) and EN 81-72 life safety directives.

120-Minute Fire Barrier

Certified Class E 120 / EI 60 fire-rated stainless steel landing doors with intumescent fire seals to stop smoke, flame, and toxic gas penetration.

Dual Power Redundancy

Fire-resistant FRLS electrical harnesses with automatic dual-power changeover to building emergency standby generators within 30 seconds.

Smoke Ingress Barrier

Seamless integration with building HVAC dampers to maintain positive air pressure in the shaft and cabin, keeping escape routes 100% smoke-free.

Emergency Key Override

Dedicated master key switch returns the car non-stop to ground floor (Phase I) and places the lift under exclusive firefighter car control (Phase II).

LIFE SAFETY & STATUTORY MATRIX

Fire Evacuation Lift Technical Parameters

Mandatory high-rise life safety configurations certified in strict compliance with NBC 2016 Part 4, EN 81-72, and local Fire Department norms.

SpecificationStandard Fireman LiftHigh-Rise Evacuation Setup
Carrying Capacity8 to 13 Passengers (544 kg – 884 kg)15 to 26 Passengers / Stretcher (1020 kg – 2000 kg)
Travel Speed Range1.0 m/s – 1.5 m/s1.75 m/s – 2.5 m/s (Ground to Top in < 60s)
Door Fire Rating2-Hour Fire Integrity (E 120 Minutes)2-Hour Fire & Thermal Insulation (EI 120 Minutes)
Cabling & Circuit IntegrityFRLS / Halogen-Free Fire Survival CableCWZ Certified (950°C Fire, Water & Impact Tested)
Emergency Power TransferAuto-Transfer to DG Power in ≤ 15 SecondsDual Independent Feeder + Secondary Battery ARD
Water Protection RatingIPX3 Landing & Cabin Electrical FixturesIP54 Protected Shaft Floor & Pit Drain Sensors
Emergency Roof Hatch600 mm × 400 mm Trap Door with InterlockQuick-Release Hatch + Integrated Telescopic Ladder
Fireman CommunicationDedicated 2-Way Intercom to Building ControlDirect Hardwired Hands-Free Fire Command Link
Statutory ComplianceNBC 2016 Part 4 & BIS 14665EN 81-72 (Firefighters) & EN 81-76 (Evacuation) Certified
FIRST-RESPONDER CONTROL HARDWARE

Emergency Control Interfaces & Egress Hardware

Equipped with standardized firefighter key consoles, water protection barriers, and ceiling emergency egress trapdoors.

MANDATORY CONTROL

Phase 1 & 2 Firefighter Overrides

The ground-floor key switch instantly recalls car nonstop to the designated exit floor (Phase 1) and transfers exclusive in-cabin drive control to the fire crew (Phase 2).

WATER PROTECTION

Fire Hose Water-Diverting Canopy

Roof runoff drainage deflectors and IP54 sealed electrical connections protect lift systems from water damage discharged by fire hose reels and sprinklers.

SAFETY EGRESS

Roof Escape Hatch with Ladder

High-strength cabin roof trapdoor ($500\text{mm} \times 700\text{mm}$) with electrical interlock safety switches and a telescopic ladder for emergency shaft rescue.

FIRE SAFETY CONSULTANTS, ARCHITECTS & MEP ENGINEERS

Need Fire Department NOC Compliance & Hoistway GA CAD Drawings?

Download compliant General Arrangement blueprints detailing electrical switchgear dual-feed routing, shaft positive pressurization vents, and fire lobby vestibule clearances.

24/7 RAPID ASSISTANCE

Facing a Lift Breakdown or Need an Existing AMC Audit?

Call our direct technical desk for immediate breakdown support or request a free on-site safety evaluation of your current elevator system.